What a conventional fire alarm system includes
In a conventional system each zone is one circuit from the panel. When any detector or call point on that circuit operates, the panel shows the zone in alarm and switches on the sounders. The range on this page covers every part of such a system.
- Zone panels: Eaton Firedex FX2202, FX2204 and FX2208 (2, 4 and 8 zones), the EFCV8Z-NB 8 zone and CF50016 16 zone panels, and Ravel RE-104 (4 zones) and RE-9012 (12 zones, expandable). Ravel RE-120GR and RE-25AR panels add agent release outputs for gas suppression.
- Two wire panels: Eaton Ultra Bi-Wire panels in 2, 4 and 8 zones, where detectors, call points and sounders share the same two wires, with matching Bi-Wire detectors, call points and base sounder beacons.
- Detectors: Hochiki photoelectric smoke and heat detectors (fixed and rate of rise, with a marine version), intrinsically safe smoke and heat detectors and IFD flame detectors for hazardous areas, and Eaton optical, multi-sensor and heat detectors.
- Call points: Hochiki standard, weatherproof and intrinsically safe call points, Eaton CX201 and weatherproof CX203, and Ravel call points and pull stations.
- Warning devices: Eaton 6 and 8 inch 24 V bells and Solex beacon, Hochiki visual alarm beacons, and Ravel RE-24CS hooter and RE-24SS hooter with strobe.
- Parts: detector bases, call point covers and spare glasses, end of line modules, remote indicators, duct detector housings, a 24 V magnetic door retainer, and Firedex and Ravel repeater panels.
How to choose a conventional fire alarm panel and devices
- Count your zones: plan one zone per floor or fire area, then pick a panel with a few spare zones.
- Bi-Wire to save cable: a two wire panel suits refits and sites where pulling extra cable is costly.
- Detector type: smoke for rooms and corridors, heat for kitchens, pantries and boiler rooms, intrinsically safe or flame detectors where flammable gas or dust is present.
- Weatherproof devices: use weatherproof call points outdoors, in car parks and in wash-down areas.
Conventional fire alarm system price in India
The cost depends on the number of zones, the brand, how many detectors, call points and sounders you need, and the cable run. Each product on this page shows a starting price as a guide, before GST. The final price comes with your quote and depends on the options and quantity you need.
Buy conventional fire alarm parts from Drown Fire
We supply conventional fire alarm panels and devices from Eaton, Hochiki and Ravel, with red FRLS fire alarm cable. For larger buildings, see our addressable fire alarm system range. Every order comes with a GST invoice and Pan-India delivery.